Compound Arch — Two Internal Hinges

Fixed-pin arch with two internal hinges, a 90 kN vertical crown load and a 40 kN horizontal side load; all four segments carry compression (arch action), and the fixed wall supplies a 120 kN·m moment reaction.

Category: frame · Difficulty: Expert

Solution

Support reactions (solver-verified)
SupportRx (N)Ry (N)Mz (N·m)
A-8545-120
D45450

Open this example in StatIQ

All reaction values are computed by the StatIQ structural engine, not generated text. Signs follow the solver's convention: a positive Ry acts upward, a negative Ry downward; a positive M is counter-clockwise.